autstat Support

icon
Avatar
dirienzo.julio
Posts: 5
Hi Thomas
Is there any compatibility issue with version previous to Windows 10?
2017-03-07 15:16
Avatar
Thomas Baier
Moderator
Posts: 222
Julio,

not that we know of. There have been a few reports on a problem on startup, which we have identified and fixed, but I am not aware that this is a compatibility issue with Windows 7.

If you know of a problem, you should clarify this.

Thomas
2017-03-07 15:20
Avatar
dirienzo.julio
Posts: 5
Users running Windows 7 or lesser you can see the starting windows of statconnDCOM, but after that
the conection is not stablished.

When running Server 01 Basic Test
it gives the following message

Run-Time error '-2147023170 (800706be)';
Automation error
2017-03-07 16:15
Avatar
Thomas Baier
Moderator
Posts: 222
Cannot say anything without diagnostics information.

Is the software in question correctly licensed? Home users? Students?
2017-03-07 16:34
Avatar
Raul Muñoz
Posts: 1
Me as Julio, get the same error message in Windows 7.
I'm using the licensed version of statconnDCOM, the latest version of the program (3.6-0B4 HomeStudent)

Regards!
2017-03-16 04:17